Optimize irrigation with Rotor automatic filtration

Customer request:

At a major golf club , there were issues related to certain fungi present in the water of the lake used to irrigate the golf courses. The To prevent the growth of these fungi, the client had constructed a second lake, at a suitable distance from the first one, into which the water could be transferred after it had purified. In order to apply the correct dosages of chemicals, it was necessary to remove solid particles and any solid contaminants.

SATI Solution:

To ensure filtration of 25 μm and remove solids, fungi, and impurities that hinder the antibacterial treatment, SATI employs a three-stage system.

  • Primary and Secondary Filtration: Automatic Filter “O” Rotor with pre-filter of 3,000 μm and self-regenerating system of 120 μm.
  • Final Aging: Filter “L” Rotor with 25 μm to remove fungi and solids, optimizing the antibacterial chemical processes.
  • Irrigation Protection: Rotor Filter, 120 μm located at the lake outlet to prevent nozzle clogging.